Toray东丽 氧气分析仪 RF-400
- 产品名称:Toray东丽 氧气分析仪 RF-400
- 产品型号:RF-400 ,LC-750H/PC-111
- 产品厂商:Toray 东丽
- 产品文档:
Toray东丽 氧气分析仪 RF-400
的详细介绍
Toray东丽 氧气分析仪 RF-400(我司销售的Toray氧气分析仪器我们负责维修点检!?。?/u>
品牌:TORAY东丽 氧气分析仪RF-400
型号:RF-400
用途:用于烘烤炉、N2 回流焊炉和脏气的氧气分析仪
特点:
新型粒子过滤器无需从设备中取出氧气分析仪即可更换
特殊过滤器提高氧传感器的耐用性
交流范围支持100V至240V交流电源
方便的测量范围测量范围为0至10000 ppm,通常用于氮气回流焊系统(0–1% 范围也可?。?
结构紧凑,易于安装深度比传统设备短,节省空间。
RF-400, LC-750H/PC-111
Model: RF-400
-
New particle filter
Replaceable without removing the oxygen analyzer from the device -
Special filter
-
Improves oxygen sensor durability
-
Wide AC range
Supports 100 V to 240 V AC power -
Convenient measurement range
Measurement range of 0 to 10,000 ppm, commonly used in nitrogen reflow systems (0–1% range is also selectable) -
Compact and easy to install
Shorter depth than conventional devices. Save space.
RF-400 specifications
| Measurement principle | Zirconia concentration cell type | ||
|---|---|---|---|
| Type | Desktop type/panel mounted type | ||
| Display system | 4-digit digital display (concentration display) | ||
| Measurement range |
0-1 / 10 / 100 / 1000 / 10000ppm(1) / 10 / 100vol%O2 10-20~10-0atm Automatic range |
||
| Repeatability |
Within ±1% of full scale; 1%≦ sample gas ≦100% Within ±2% of full scale; 10 ppm≦ sample gas ≦1% Concentrations under 10 ppm are out of warranty. |
||
| Sampling method | Continuous suction with built-in pump | ||
| Sample gas requirements | Pressure | Pressurization of 30 KPa or less | |
| Flow rate | 1,000~2,000mL/min | ||
| Humidity | Dew point below ambient temperature | ||
| Temperature | 0 to 50°C | ||
| Others | Must not contain corrosive gas (fluorine gas, chlorine gas, sulfuric gas, etc.), gas containing organic silicone, flammable substances (including gas), oil or moisture | ||
| Reference gas | Atmosphere | ||
| Recorder output | Oxygen concentration output |
4-20mA; insulated,load resistance of 550 Ω or less Recorder output range taken as full scale, and oxygen concentration given in linear output |
|
| Output range | 0-100%, 0-10%, 10000ppm, 0-100ppm, 0 Automatic/fixed range | ||
| Transmission output | RS-232C (optional) | ||
| Alarm output | FAIL (device error) | 1 point |
Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.5 A or less Contact point closes when device error occurs (contact point operation is adjustable) |
| ALM (concentration alarm) | 2 points (H/L) |
Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.5 A or less Contact point closes when alarm occurs (contact point operation is adjustable) |
|
| RDY (warmup signal) | 1 point |
Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.5 A or less
|
|
| Warmup time | 5 minutes or less | ||
| Dimensions | Body | 210 mm (W) ×134 mm (H)×300 mm (D)(excluding projecting parts and filter) | |
| Weight | Approx. 6.5 kg | ||
| Gas connection | INLET | Rc1/4 | |
| BYPASS OUT | Rc1/4 | ||
| OUTLET | Rc1/4 | ||
| Power | 100 to 240 V AC±5%, 200 V A 50 Hz/60 Hz±2% | ||
| Toray东丽 氧气分析仪 RF-400(我司销售的Toray氧气分析仪器我们负责维修点检!?。?/span> |